![HP ESG-D Series User Manual Download Page 350](http://html.mh-extra.com/html/hp/esg-d-series/esg-d-series_user-manual_160473350.webp)
5-214
Hardkey and Softkey Reference
Mode - NADC
In this example:
•
G: --
- Guard time is a 6-bit field. The text in this field is grey, indicating that you
cannot change the contents of the guard time field.
•
R: --
- Ramp time is a 6-bit field. The text in this field is grey, indicating that you
cannot change the contents of the ramp time field.
•
Data: PN9
- Indicates that the data selection for this up traffic channel is PN9. Press
the
Data
softkey in the Configure Up TCH menu to change the data selection. Other
selections allowed include PN15, fixed 4-bit patterns, fixed patterns of ones and zeroes,
user files, or external data.
•
SYNC: A91DE4A
- Indicates that the synchronization word is set to hexadecimal
A91DE4A. Press the
SYNC
softkey in the Configure Up TCH menu to change the
contents of the synchronization word field.
•
SACCH: 000
- Indicates that the slow associated control channel is set to hexadecimal
000. Press the
SACCH
softkey in the Configure Up TCH menu to change the contents
of the slow associated control channel field.
•
CDVCC: 000
- Indicates that the coded digital verification color code is set to
hexadecimal 000. Press the
CDVCC
softkey in the Configure Up TCH menu to change
the contents of the coded digital verification color code field.
Softkey Location: Press
Mode
,
NADC
,
Data Format Pattern Framed
,
Configure Timeslot
,
Configure Up TCH
Summary of Contents for ESG-D Series
Page 4: ...ii ...
Page 34: ...Contents 30 ...
Page 46: ...1 12 Preparing for Use Verifying Signal Generator Operation ...
Page 138: ...5 2 Hardkey and Softkey Reference ...
Page 164: ...5 28 Hardkey and Softkey Reference Amplitude ...
Page 166: ...5 30 Hardkey and Softkey Reference Arrow Keys ...
Page 168: ...5 32 Hardkey and Softkey Reference Display Contrast Keys ...
Page 188: ...5 52 Hardkey and Softkey Reference FM ...
Page 196: ...5 60 Hardkey and Softkey Reference Frequency ...
Page 198: ...5 62 Hardkey and Softkey Reference Help ...
Page 200: ...5 64 Hardkey and Softkey Reference Hold ...
Page 202: ...5 66 Hardkey and Softkey Reference Incr Set ...
Page 236: ...5 100 Hardkey and Softkey Reference LF Out ...
Page 238: ...5 102 Hardkey and Softkey Reference Local ...
Page 240: ...5 104 Hardkey and Softkey Reference Mod On Off ...
Page 242: ...5 106 Hardkey and Softkey Reference Mode ...
Page 336: ...5 200 Hardkey and Softkey Reference Mode GSM ...
Page 422: ...5 286 Hardkey and Softkey Reference Mode PDC ...
Page 466: ...5 330 Hardkey and Softkey Reference Mode PHS ...
Page 532: ...5 396 Hardkey and Softkey Reference Numeric Keypad ...
Page 554: ...5 418 Hardkey and Softkey Reference Power Switch ...
Page 564: ...5 428 Hardkey and Softkey Reference Preset ...
Page 570: ...5 434 Hardkey and Softkey Reference Pulse ...
Page 574: ...5 438 Hardkey and Softkey Reference Recall ...
Page 576: ...5 440 Hardkey and Softkey Reference Return ...
Page 578: ...5 442 Hardkey and Softkey Reference RF On Off ...
Page 584: ...5 448 Hardkey and Softkey Reference Save ...
Page 604: ...5 468 Hardkey and Softkey Reference Sweep List ...
Page 666: ...7 20 Operation Userfile Applications ...
Page 675: ...8 9 Safety and Regulatory Declaration of Conformity Declaration of Conformity ...