Trigger position out of bounds: <bounds> (Error 1202)
Cause: This error occurs when you attempt to specify a number of lines to appear
either before or after the trigger which is greater than the number of lines allowed.
The <bounds> string indicates the incorrect range you typed (not the correct limits
on the range).
Action: Be sure that the trigger position specified is within the range -1024 to 1023
(or -512 to 511 if counting is enabled).
trig1 break (Async_Stat 618)
Cause: This status message will be displayed if you used the break_on_trigger
syntax of the trace command and the analyzer has found the trigger condition
while tracing a program run. The emulator is broken to the monitor.
Trig1 signal cannot be driven and received (Error 1302)
Cause: This error occurs when you attempt to specify the internal trig1 signal as the
trace arm condition while the same analyzer’s trigger output is currently driving the
trig1 signal. This error also occurs if you attempt to specify that the trigger output
drive the internal trig1 signal while that signal is currently specified as the arm
condition for the same analyzer.
Action: You can either change the arm or the trigger output specification; in either
case, make sure they do not use the same internal signal.
trig2 break (Async_Stat 619)
This status message will be displayed if you have used the internal trig2 line to
connect the analyzer trigger output to the emulator break input and the analyzer has
found the trigger condition. The emulator is broken to the monitor.
Trig2 signal cannot be driven and received (Error 1303)
Cause: This error occurs when you attempt to specify the internal trig2 signal as the
trace arm condition while the same analyzer’s trigger output is currently driving the
trig2 signal. This error also occurs if you attempt to specify that the trigger output
drive the internal trig2 signal while that signal is currently specified as the arm
condition for the same analyzer.
Action: You can either change the arm or the trigger output specification; in either
case, make sure they do not use the same internal signal.
Chapter 12: Emulator Error Messages
Trigger position out of bounds: <bounds> (Error 1202)
435
Summary of Contents for 64780A
Page 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Page 20: ...xx ...
Page 21: ...Part 1 Quick Start Guide 1 ...
Page 23: ...1 Getting Started 3 ...
Page 45: ...Part 2 Using The Emulator 25 ...
Page 47: ...2 Plugging into a Target System 27 ...
Page 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Page 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Page 69: ...4 Entering Commands 49 ...
Page 103: ...5 Configuring the Emulator 83 ...
Page 122: ...102 ...
Page 123: ...6 Using the Emulator 103 ...
Page 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Page 249: ...8 Making Software Performance Measurements 229 ...
Page 279: ...9 Making Coordinated Measurements 259 ...
Page 295: ...Part 3 Reference 275 ...
Page 297: ...10 Setting X Resources 277 ...
Page 312: ...292 ...
Page 313: ...11 Emulator Analyzer Interface Commands 293 ...
Page 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Page 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Page 422: ...402 ...
Page 460: ...440 ...
Page 461: ...Part 4 Concept Guide 441 ...
Page 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Page 471: ...Part 5 Installation and Service Guide 451 ...
Page 473: ...14 Installation 453 ...
Page 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Page 493: ...15 Installing Updating Emulator Firmware 473 ...
Page 500: ...480 ...
Page 516: ...496 ...
Page 540: ...520 ...