FATAL SYSTEM SOFTWARE ERROR (Error 204)
FATAL SYSTEM SOFTWARE ERROR (Error 205)
FATAL SYSTEM SOFTWARE ERROR (Error 208)
Cause: The system has encountered an error from which it cannot recover.
Action: Write down the sequence of commands that caused the error. Cycle power
on the emulator and reenter the commands. If the error repeats, call your local HP
Sales Office for assistance.
File could not be opened
Cause: The file cannot be opened or created for writing.
Action: Check to make sure that the parent directory for the file has correct
permissions set.
File transfer aborted (Error 410)
Cause: A transfer operation was aborted due to a break received, most likely a
<CTRL> c from the keyboard. If you typed <CTRL> c, you probably did so
because you thought the transfer was about to fail.
Action: Retry the transfer, making sure to use the correct command options. If you
are unsuccessful, make sure the data communications parameters are set correctly
on the host and on the HP 64700; then retry the operation.
Foreground monitor handled an exception: vector offset 8 (Async_Err 152)
Cause: The foreground monitor handled an exception while performing a monitor
command (such as read/write user memory).
Action: Verify memory operation and retry your command.
Foreground monitor not mapped into emulation memory (Error 141)
Cause: You tried to map the foreground monitor into memory space that is not
mapped as emulation memory. The foreground monitor must be mapped into
emulation memory space.
Action: Respecify map term 1 to be located in emulation memory space.
Chapter 12: Emulator Error Messages
FATAL SYSTEM SOFTWARE ERROR (Error 204)
FATAL SYSTEM SOFTWARE ERROR (Error 205)
416
Summary of Contents for 64780A
Page 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Page 20: ...xx ...
Page 21: ...Part 1 Quick Start Guide 1 ...
Page 23: ...1 Getting Started 3 ...
Page 45: ...Part 2 Using The Emulator 25 ...
Page 47: ...2 Plugging into a Target System 27 ...
Page 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Page 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Page 69: ...4 Entering Commands 49 ...
Page 103: ...5 Configuring the Emulator 83 ...
Page 122: ...102 ...
Page 123: ...6 Using the Emulator 103 ...
Page 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Page 249: ...8 Making Software Performance Measurements 229 ...
Page 279: ...9 Making Coordinated Measurements 259 ...
Page 295: ...Part 3 Reference 275 ...
Page 297: ...10 Setting X Resources 277 ...
Page 312: ...292 ...
Page 313: ...11 Emulator Analyzer Interface Commands 293 ...
Page 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Page 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Page 422: ...402 ...
Page 460: ...440 ...
Page 461: ...Part 4 Concept Guide 441 ...
Page 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Page 471: ...Part 5 Installation and Service Guide 451 ...
Page 473: ...14 Installation 453 ...
Page 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Page 493: ...15 Installing Updating Emulator Firmware 473 ...
Page 500: ...480 ...
Page 516: ...496 ...
Page 540: ...520 ...