Example
Set the width of the address label column to 30 characters and the width of the
mnemonic column to 50 characters:
set width label 30 mnemonic 50
To select the type of count information in the
trace list
•
Choose Trace
→
Display Options... and in the dialog box, select Count Format
Relative or Absolute, as desired. Then click the OK or Apply pushbutton.
•
To display count information in the trace list relative to the trigger state, enter:
display trace count absolute
•
To display count information in the trace list relative to the previous trace list state,
enter:
display trace count relative
The count information in the trace list is always displayed if it is turned on. To turn
on the trace counting function, enter a command beginning with trace counting on
the command line. Refer to "To count states or time" later in this manual for
details.
When using the 1K analyzer, the trace memory is 512 states deep if counting states
or time is turned on and 1024 states deep if counting is turned off. To disable
counting in the 1K analyzer, use the command trace counting off. When using the
deep analyzer, full memory depth is always available; the depth of the deep
analyzer is not affected by the counting selected. See “To count states or time.”
Chapter 7: Using the Emulation-Bus Analyzer
Displaying the Trace List
199
Summary of Contents for 64780A
Page 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Page 20: ...xx ...
Page 21: ...Part 1 Quick Start Guide 1 ...
Page 23: ...1 Getting Started 3 ...
Page 45: ...Part 2 Using The Emulator 25 ...
Page 47: ...2 Plugging into a Target System 27 ...
Page 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Page 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Page 69: ...4 Entering Commands 49 ...
Page 103: ...5 Configuring the Emulator 83 ...
Page 122: ...102 ...
Page 123: ...6 Using the Emulator 103 ...
Page 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Page 249: ...8 Making Software Performance Measurements 229 ...
Page 279: ...9 Making Coordinated Measurements 259 ...
Page 295: ...Part 3 Reference 275 ...
Page 297: ...10 Setting X Resources 277 ...
Page 312: ...292 ...
Page 313: ...11 Emulator Analyzer Interface Commands 293 ...
Page 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Page 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Page 422: ...402 ...
Page 460: ...440 ...
Page 461: ...Part 4 Concept Guide 441 ...
Page 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Page 471: ...Part 5 Installation and Service Guide 451 ...
Page 473: ...14 Installation 453 ...
Page 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Page 493: ...15 Installing Updating Emulator Firmware 473 ...
Page 500: ...480 ...
Page 516: ...496 ...
Page 540: ...520 ...