Using the Embedded Web Server
102
Edge Switch 2/24 Installation Guide
Configure Switch and Fabric Parameters
Perform this procedure to configure the following switch and fabric operating
parameters: Buffer-to-Buffer Credit (BB_Credit), Error Detect Time Out Value
(E_D_TOV), and Resource Allocation Time Out Value (R_A_TOV), preferred
domain ID, and switch priority.
Configure Switch Parameters
The switch must be set offline to configure operating parameters. To configure the
parameters:
1. Set the switch offline as follows:
a.
Choose Operations >Online State to display the Online State tab.
b.
Click Set Offline. The message “
Your changes have been
successfully activated
” displays.
2. Click Configure at the left side of the panel. The Configure panel opens with
the Ports page displayed.
3. Choose Switch >Parameters to display the Operating Parameters tab
(
Figure 41
).
Figure 41: Switch page—Parameters tab
4. Set the switch parameters:
a.
In Preferred Domain ID, enter a value between 1 and 31 (default is 1).
The domain ID uniquely identifies each switch in a fabric.
All fabric-attached switches must have unique domain IDs. If the value is
not unique, the E_Port connection to the switch segments and the switch
cannot communicate with the fabric.
Summary of Contents for 316095-B21 - StorageWorks Edge Switch 2/24
Page 10: ...Contents 10 Edge Switch 2 24 Installation Guide ...
Page 18: ...About this Guide 18 Edge Switch 2 24 Installation Guide ...
Page 38: ...Switch Features 38 Edge Switch 2 24 Installation Guide ...
Page 46: ...Rack Mount Instructions 46 Edge Switch 2 24 Installation Guide ...
Page 96: ...Installing and Configuring the Edge Switch 2 24 96 Edge Switch 2 24 Installation Guide ...
Page 116: ...Using the Embedded Web Server 114 Edge Switch 2 24 Installation Guide ...
Page 128: ...Manage Firmware Versions 124 Edge Switch 2 24 Installation Guide ...
Page 154: ...Index 150 Edge Switch 2 24 Installation Guide ...