7 | Optional equipment
68
60084498 • 01 • 06/2022 • en
Maintenance
WARNING
Danger of injury when working on the distributor
Ø
Always call for a second person to assist.
Ø
Use suitable accessing steps.
1. Check the distributor regularly for foreign objects.
2. Check connections and hoses every day for leakages.
Repair or replace worn or damaged hoses immediately.
3. Check the distributor and hoses every day for deposits or blockages.
Clean as required.
Pneumatics/fertiliser
hopper interface
The fertiliser distributor is connected with a fertiliser hopper via a spiral hose.
NOTE
If a different hose is used than the one provided in the scope of delivery, it must
meet these following requirements:
• Inside diameter: Ø 110 mm
• Bending radius without kinking: R 110 mm
• Resistant to oil, gasoline and chemicals
• UV resistance
• Microbe resistance
• Hydrolysis resistance
Adjusting the fertiliser
placement
The fertiliser placement optionally takes place
• through the coulter into the ground
• behind the coulter on the surface of the field
• approx. half each into the ground and on the field surface