![hopf 8024GPS Technical Manual Download Page 43](http://html1.mh-extra.com/html/hopf/8024gps/8024gps_technical-manual_2161863043.webp)
HMC
(
HOPF
M
ANAGEMENT
C
ONSOLE
)
SOFTWARE
8024GPS - GPS Sync Module - V02.00
43 / 76
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
3.6.4.5.6.3
hopf
Master/Slave-String
The
hopf
Master/Slave-String can be used to synchronize slave systems with the time data
of the master system.
The
hopf
Master/Slave-String transmits:
•
the full time information (hour, minute, second)
•
the date (day, month, year [2 digits])
•
the difference time local to UTC (hour, minute)
•
the day of the week
•
status information (announcement of DST changeover, announcement of a leap
second and the status of reception of the
hopf
Master/Slave-String source)
3.6.4.5.6.3.1 Specified Settings
Required:
The following settings are required for the synchronization of the
hopf
slave-systems:
•
Normally points of time every minute, depending on system
also every second
•
output second forerun
•
ETX on the second change; selectable: data string at the
beginning or at the end of the 59. second.
•
local time
•
9600 baud, 8 bit, 1 stop bit, no parity
Received data on the serial interface that are not specified in the pertinent
data string might disturb and interrupt the cyclic string output.
The receiving synchronization interface should be set to "transmitting on
request" for Sub-Master (Slave) Systems.