![hopf 8024GPS Technical Manual Download Page 32](http://html1.mh-extra.com/html/hopf/8024gps/8024gps_technical-manual_2161863032.webp)
HMC
(
HOPF
M
ANAGEMENT
C
ONSOLE
)
SOFTWARE
32 / 76
8024GPS - GPS Sync Module - V02.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
3.6.4.2 DCF77 - optional hardware necessary
The signal generation for the output of a DCF77 pulse (1Hz) may be configured in this panel.
For the output of this signal additional hardware (at system level) is
required (see system manual if applicable).
3.6.4.2.1 Time Base of the Transmitted DCF77 Pulse
Time Base
Local Time
Standard Time
UTC Time
In general the local time is set as the base. This time leaps forward/back 1 hour every daylight
saving time changeover. The standard or UTC time must be selected as the base if automatic
daylight saving time changeover shall be suppressed.
When setting standard time (winter time), the time offset to local summer time is minus 1 hour.
Standard time runs continuously (without time leap) throughout the whole year.
When setting UTC, the world time (formerly GMT) is used as the time base. This time base
also runs continuously (without time leap) throughout the whole year.