HMC
(
HOPF
M
ANAGEMENT
C
ONSOLE
)
SOFTWARE
8024GPS - GPS Sync Module - V02.00
37 / 76
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
3.6.4.3.5 Output inverted
– Polarity of the output Pulse
All outputs stated in the system manuals of the according devices are related to the DEFAULT
setting: Output not inverted.
If nevertheless the inverting of the output signal has to be configured the "Output inverted"
checkbox has to be enabled.
3.6.4.3.6 Special Configuration
If used, the correct settings are described in the additional system manual of the customer-
specific device.
Otherwise for S1-S8 the DEFAULT-setting (all checkboxes disabled) should not be changed
due to compatibility reasons.
3.6.4.4 Cyclic Pulse - optional hardware nesessary
The signal generation for the output of cyclic pulses may be configured in this panel.
For the output of this signal additional hardware (at system level) is
required (see system manual if applicable).
3.6.4.4.1 Cyclic Pulse every
This section is used to select the pulse to be transmitted. Possible pulses are:
•
Pulses every second: every 1, 2, 3, 4, 5, 6, 10, 12, 15, 20 or 30 seconds
•
Pulses every minute: every 1, 2, 3, 4, 5, 6, 10, 12, 15, 20 or 30 minutes
•
Pulses every hour:
every 1, 2, 3, 4, 6, 8, 12 or 24 hours