Data bits
Possible settings are:
•
8
for 8 data bits
•
7
for 7 data bits
Parity
Possible settings are:
•
No Parity
•
Even Parity
•
Odd Parity
Stop Bits
Possible settings are:
•
1
for 1 stop bit
•
2
for 2 stop bits
3.6.4.5.2 Timebase
– Timebase of the output serial data string
Timebase
Local Time
Standard Time
UTC Time
In general the local time is set as the base. This time leaps forward/back 1 hour every daylight
saving time changeover. The standard or UTC time must be selected as the base if automatic
daylight saving time changeover shall be suppressed.
When setting standard time (winter time), the time offset to local summer time is minus 1 hour.
Standard time runs continuously (without time leap) throughout the whole year.
When setting UTC, the world time (formerly GMT) is used as the time base. This time base
also runs continuously (without time leap) throughout the whole year.
3.6.4.5.3 Output scheme
The output scheme for the transmission must be selected here:
•
Without second forerun / immediate control character
•
With second forerun / immediate control character
•
With second forerun / control character every second
•
With second forerun / control character delayed every second
3.6.4.5.4 Transmission Time
•
Every Second
•
EveryMinute
•
Every Hour
•
Remote