1-1
S E C T I O N 1
General Description
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About the VISTA-128FBPN
The VISTA-128FBPN is an 8-partition, UL Listed commercial fire and burglary control panel with the following
features:
•
Up to 128 zones (hardwired, polling loop, and wireless zones)
•
Up to 150 user codes
•
Supervision of Notification Appliance Circuits, phone lines, keypads, RF receivers, and output devices
•
Scheduling capabilities (allows certain operations to be automated)
ULC
Scheduling is currently not approved for ULC applications.
The VISTA-128FBPN can interface with the following devices:
•
An ECP Communications Device that can send Contact ID messages
Features
Hardwire and Optional Expansion Zones
•
Provides 8 hardwire zones.
•
Supports up to 16 2-wire smoke detectors each on zone 1 and zone 2 (32 total).
•
Automatically resets 4-wire smoke detectors if the Aux Relay is programmed for smoke reset (3*61 = 2).
•
Supports up to 50 2-wire latching glassbreak detectors on zone 8.
•
Supports up to 119 additional expansion zones using a built-in polling (V-Plex) loop.
•
Supports up to 128 wireless zones, fewer if using hardwire and/or polling loop zones.
•
Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display
or sound the alarm).
•
Provides three keypad panic keys: 1 +
✴
(A),
✴
+ # (B), and 3 + # (C).
•
Full Status (Remote Interactive Service)
Peripherals Devices
•
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
•
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
•
Provides 96 outputs using 4204 and 4204CF Relay Modules, and V-Plex Relay Modules can activate outputs in
response to system events (alarm condition), at a specific time of day, at random times, and manually using the #70
Relay Command Mode.
•
Supports one additional style-Y supervised Notification Appliance Circuit using a 4204CF.
•
Supports the ADEMCO 4146 Keyswitch on any one of the system's eight partitions.
•
Can be used with Commercial Fire Listed 24VDC Power Supplies.
Arming/Disarming and Bypassing
•
Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be
programmed to automatically unbypass when the zone restores.
•
Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the exit
delay expires, otherwise an alarm is generated.
UL
•
Vent zones cannot be used in UL installations.
•
You
must disable the Force Arm option (used in conjunction with the Arm w/Fault option), in UL installations.
Summary of Contents for VISTA-128FBP
Page 2: ......
Page 8: ...viii ...
Page 62: ...VISTA 128FBPN Installation and Setup Guide 4 10 ...
Page 98: ...VISTA 128FBPN Installation and Setup Guide 8 2 ...
Page 108: ...VISTA 128FBPN Installation and Setup Guide 10 6 ...
Page 116: ...VISTA 128FBPN Installation and Setup Guide C 2 ...
Page 120: ...VISTA 128FBPN Installation and Setup Guide D 4 ...