Rev. D
8
KDMU000799
02/6/04
2.2
RECEIVER BOARD, CONTINUED
2.2.3 Addressing
Each UltraDome KD6i must be given a unique address (camera number) set by the
operator at the control system to control the scan. The address is defined using rotary
switches S1, S2, and S3 on the receiver board. Addresses are set from 001 to 989.
Addresses 990 to 999 are reserved for factory testing. If the switches are set to 000,
the scan responds to all commands with all addresses and there is no communication
error checking.
ADDRESS
S1
Ones Digit
S2
Tens Digit
S3
Hundreds Digit
The addressing scheme is modulo 256. The scan is physically addressed 1-989,
but all scans addressed above 256 must be controlled using camera numbers 1-255.
NOTE:
If the control system is set for MUX-100 (19.2K) protocol, addresses
256, 512, and 768 cannot be used. These are unattainable values in a
MUX-100 control packet.
NOTE:
The three address switches, S1, S2, and S3, must be set to 0, 0, 0 when the
KD6i is installed in a back can with the digital interface board and is installed
in a network.
NOTE:
If you are using the KD6i with control equipment other than Ultrak Diamond
series, please consult the instruction manuals provided with your control
equipment for addressing the dome. For example, if you are using a
Maxpro control system, the addressing scheme is 1-16. The KD6i address
is determined by the switch settings and the port the KD6i is connected to on
the switch.
Another example is if you are using the scan with the
Manchester Code
Interface Board and an American Dynamics control system
, the
addressing scheme is 1-64, the same addressing scheme as an AD switch.
Refer to the manuals provided with your control system for help in
addressing the KD6i dome.
Refer to
Table 1
to cross reference camera addresses to camera control numbers
using modulo 256.