Rev. D
6
KDMU000799
02/6/04
2.2
SCAN MODULE INSTALLATION, CONTINUED
2.2.1
Defining Protocol (Switches 1-4)
Protocol
1
2
3
4
Standard
Diamond
OFF OFF OFF OFF
Maxpro
ON
OFF
OFF
OFF
MUX100
OFF
ON
OFF
OFF
AD
ON
ON
OFF
OFF
Pelco
P
OFF
OFF
ON
OFF
VCL
ON OFF ON OFF
Pelco
D
OFF ON ON OFF
iPro
ON
ON
ON
OFF
Pelco
P_AD OFF
OFF
ON
ON
Pelco
D_AD OFF
ON
ON
ON
Equipment
Protocol
Javelin equipment
Set the Javelin controller for Diamond protocol and
set the KD6i unit for Maxpro protocol.
KD6i with an AD1281/1 Code
Distributor
Set the KD6i to American Dynamics protocol.
KD6i with a Sennetech Code
Translator, Model SCT-1036
Set the KD6i to Maxpro protocol.
KD6i with the Manchester
Code Interface Board and an
AD control system
Set the KD6i to American Dynamics protocol.
KD6i with the Manchester
Code Interface Board and a
Burle control system
Set the KD6i to Maxpro protocol.
KD6i with the Digital Interface
Set the KD6i address to 000 and the control system
to UPF. Set the KD6i to standard (Diamond)
protocol.
NOTE:
If the switches are set to something other than the above settings, the scan
defaults to Standard protocol.
The standard Pelco P and D selections use special PreShots numbered in
the 80’s and 90’s. The Pelco P w/AD PreShots and the Pelco D w/AD
PreShots selections set the protocol for Pelco P and Pelco D code
respectively, but use special PreShot numbers less than 32 for KD6i menus
and setup.