PROGRAMMING SECTOR IDs
Sector IDs are used for labeling specific areas that the scan views. Whenever a scan
unit is under manual control and it is viewing a programmed sector, the name given
that sector is added to the video signal.
NOTE:
The camera ID display must be enabled. When an operator is viewing the
monitor or a video-tape machine is recording a specific dome, this labeling
provides a quick reference for the area being displayed. Up to 16 Sector
IDs can be programmed for each Scan Unit.
To program a Sector ID (in the control camera displayed on the controller),
perform the following steps.
1. Press
SHIFT + F8
.
2. Type
a
Sector number (0-15)
and press
Enter
.
3. Type
the
Sector title
(up to 24 characters) and press
Enter
.
The following options are available:
E
to Edit Sector
D
to Delete Sector
S
to Save Sector Coordinates
N
to Save Name Only
4. Press
S
to program and save sector
coordinates. Refer to the diagram for
programming coordinates.
5. Using the controller, move the scan
so the
lower left corner
of the sector
is centered on the monitor, then
press
Enter
. (The crosshair function
may be helpful in determining the
center of the monitor.)
Right pan
Top tilt
Bottom tilt
Left pan
6. Using the large joystick on the controller, move the scan so the
upper right
corner
of the sector is centered on the monitor, then press
Enter
. If the upper
right tilt position is below the lower left tilt position, the message “Illegal Tilt
Direction” is displayed. Readjust the tilt position until the message disappears or
press
ESC
to cancel the operation and return to manual operation.
7. Repeat steps 2-6 to continue programming sectors or press
ESC
to return to
manual operation.