Enhanced Micro TDC 3000 User’s Manual
5-21
9/95
5.4.2
10.
AUTO SIZE/POSITION SET UP BUTTON (ON/OFF)
AUTO
SIZE
-
Use to operate or cancel the automatic horizontal and vertical picture
sizing and centering function which recognizes the picture size and
position according to the signal applied to the monitor and adjusts
automatically.
-
The indicator will be illuminated when the automatic function is on.
-
While the automatic function is on, it operates every time you turn the
power on or change the input signal. It is best to keep the button off
when it is not necessary.
Note
-
When you operate the automatic function, you will need full-
size picture information on the screen and the video input
signal with the maximum brightness such as Windows screen.
It may not operate properly with special picture information
such as only a prompt C> on the screen.
-
When the picture adjusted by the automatic function needs to
be changed, operate the SIZE or POSITION BUTTON you
desire to change.
11.
AUTO CONTRAST SET UP BUTTON (ON/OFF)
AUTO
CONT
-
Use to operate or cancel the AUTO CONTRAST SENSOR.
-
The indicator will be illuminated when the sensor is in operation.
Note
-
When set to ON it will automatically adjust the crt contrast as
the ambient light of the room changes.
12.
AUTO POWER-OFF SET UP BUTTON (ON/OFF)
AUTO
POWER
-
Use to operate or cancel the AUTO POWER-OFF SENSOR.
-
The indicator will be illuminated when the sensor is in operation.
Note
-
When set to ON it will sense the presence of an operator in
front of the monitor. It will automatically power down the
monitor when an operator is absent for more than an hour.
The power indicator will be green in a normal operation and
red when in stand-by-state. To restore operation, either cycle
power or press the AUTO POWER button (cancels sensor).
13.
RRC CONTROL BUTTONS
-
Press to correct raster rotation or poor purity caused by magnetism when the
monitor is swiveled while in operation.
-
When you press the RRC CONTROL BUTTONS at the same time for over
three seconds, you will hear a beep, and the adjusted condition will be canceled
and set back to the factory setting “center.”
Note: -
The RRC CONTROL BUTTONS must be used after degauss has been
operated.
52542
Summary of Contents for Enhanced Micro TDC 3000
Page 1: ...L 8 Node Enhanced Micro TDC 3000 User s Manual MT11 520 ...
Page 2: ......
Page 10: ...Enhanced Micro TDC 3000 User s Manual iv 9 95 ...
Page 56: ...Enhanced Micro TDC 3000 User s Manual 3 8 9 95 ...
Page 82: ...Enhanced Micro TDC 3000 User s Manual 4 26 9 95 ...
Page 128: ...Enhanced Micro TDC 3000 User s Manual 5 46 9 95 ...
Page 144: ...Enhanced Micro TDC 3000 User s Manual 6 16 9 95 ...
Page 156: ...Enhanced Micro TDC 3000 User s Manual B 4 9 95 ...
Page 168: ...Enhanced Micro TDC 3000 User s Manual Index 12 7 95 ...
Page 171: ......