Sc.O… Description
01:143_0
for the beginning of each month at midnight
02:143_0
for the beginning of each month at 6am
The daily limit "6am" (monthly limit) can be changed via
Serv.
Date and time
DayB
.
01:142_0
for the beginning of each day at midnight
02:142_0
for the beginning of each day at 6am
The daily limit 6am (monthly limit) can be changed via
Serv.
Date and time
DayB
.
01:403_0
at the beginning of every hour
−
Press the ENTER key to confirm the set value. It is possible to abort the entry by pressing the ESC
key.
c) Setting up pulse duration:
i
Parametrization of the pulse duration via the EK280 keyboard is only possible with software
version 2.20 or later.
Older software versions may be programmed using enSuite via "
Parameterize online
" >
"
Parameters
" and the paths described (
i
The pulse duration can be set as a multiple of 125 ms for each output.
−
When in the corresponding menu press the key
until
"PW.O1"
,
"PW.O2"
,
"PW.O3"
or.
"PW.O4"
is
displayed.
−
Press the ENTER key.
⇒
The actual parameterized value flashes.
−
Move the cursor to the digits using the
or
arrow keys and update them using the
or
arrow
keys to set the desired period.
−
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
6.5 Event-output
Each of the outputs 1 to 4 (terminals DA1 to DA4) can be programmed as an event-synchronized output.
An event output basically functions as a status output (
), however the pulse duration can also
be set. In the case of a status output, however, the pulse lasts as long as the corresponding status message.