![Honeywell Elster EK280 Applications Manual Download Page 44](http://html.mh-extra.com/html/honeywell/elster-ek280/elster-ek280_applications-manual_151826044.webp)
EK280
Application Manual
42
6.1 Connection of outputs
Danger!
For EK280 with internal power supply, the mains voltage must be switched off before
opening the housing, ensure it is not turned back on and verify that there is no voltage.
+ -
DA1
+ -
DE1
Downstream device,
e.g. DL220
−
Connect the device to one of the desired digital outputs (terminals "DA1" to "DA4") on the EK280.
6.2 LF pulse output (low-frequency)
Each of the outputs 1 to 4 (terminals DA1 to DA4) can be programmed as a low-frequency pulse output.
6.2.1 Parameterization
Parameterization is carried out via the keyboard on the EK280.
Alternatively, parametrization can be carried out using the
enSuite
program. The paths which are
subsequently described can be found in
enSuite
under "
Parameterize online
" > "
Parameters
".
a) Setting up the output mode:
−
Move the cursor to register "
Serv.
"and along the following path to the mode for the corresponding
output
"Md.O1"
to
"Md.O4"
:
Serv.
Outputs
Output 1
Md.O1
Serv.
Outputs
Output 2
Md.O2
Serv.
Outputs
Output 3
Md.O3
Serv.
Outputs
Output 4
Md.O4
i
The low-frequency pulse output of the EK280 can be operated with active or inactive logic.
The output mode must be programmed accordingly for this purpose (see below).
−
Press the ENTER key.
⇒
The actual parameterized value flashes.