EK280
Application Manual
187
−
Additionally you can configure up to 10 free SMS layouts, with enSuite change to related sub-menu
"Layout 1"
–
"Layout 10"
.
−
At the free layout menu you can define up to 15 sources and assign a name for this layout:
i
In address range 1:8D0 up to12:8D0 you can define user texts, which can be used for SMS
messages for additional text information
b) Configure recipients of SMS
−
You can define up to 2 recipients per SMS message, with enSuite change to sub-menu "
Interfaces
"
> "
Telephone book
".
−
Choose free entries of the EK280 phone book and change to the related sub-menu:
r) Configure message transmission
−
With enSuite change to sub-menu "
SMS
" > "
Settings
"
−
You can define up to 10 SMS messages, change to the related sub-menu "
SMS 1”
up to
"SMS 10”
.
51
"xx“ = instance of free layouts (value range from 1 to 10)
Archive entry
(14)
The message contains the latest entry of the measure period profile. The
complete profile line will be transmitted.
Month end value
(15)
The message contains the latest values of Vm and Vb and their last month‘s
maximum values at end of measure period and start of gas day.
Address
"xx"
Definition
xx:761
Name of the layout, which will be copied to the message.
xx:750 up to
xx:75E
value 1 up to value 15: Declaration of sources. The content of those sources will
be copied to the message.
Telephone
book
Definition
TelNo
Phone number of the recipient including dialing code.
Name
Name of the recipient
E-Mail address of the recipient (alternative).
SForm
0 = The SMS message will be transmitted as text.
1 = The SMS message will be transmitted as binary (not readable, for evaluation
by software).
Sep
ASCII character used to separate values in the short message, e.g. 42 =
*
.
Ident
The content of the source is used to identify the sender of the short message,
e.g. 1:180 = serial number of EK280.