EK280
Application Manual
206
9.6 Modifications archive (audit trail)
Changes to settings (parameterization) is archived in the audit trail.
The content of the audit trail can be shown on the display of the device via the path
"Serv." > "Archives" >
"Audit Trail”.
i
The modifications archive is not a flexible archive.
9.6.1 Archive content
Pos. Address Display
Description
Retrievable
1
01:01F8 GONo
Global Block number
S
2
05:0A20 ABNo
Archive Block number
A + S
3
01:0400 Time
Date and time
A + S
4
05:0810 Addr
Address
A + S
5
05:0811 old
old value
A + S
6
05:0812 new
new value
A + S
7
01:0170 St.PL
Status of calibration lock
A + S
8
02:0170 St.ML
Status of manufacturer lock
A + S
9
03:0170 St.AL
Status of administrator lock
A + S
10
04:0170 St.CL
Status of customer lock
A + S
11 05:0A21 Check
Check sum result ( „CRC OK“ or „Error“)
A + S
The values can be retrieved in accordance with the information in the table via D = display and/or
I = interface.
9.6.2 Memory capacity
The archive can store the last 200 settings changes (parametrization).
i
The modification archive is a ring-type memory. If the archive is full then the oldest entries are
overwritten.
9.6.3 Deleting the modification archive
2.4.2 Clear volumes and archives ("Clr.V")
9.7 Updates archive
Attempted or completed updates of the device software are archived in the updates archive via an interface.
The content of the update archive can be shown on the display of the device via the path
"Serv." >
"Archives" > "Update archive"
.