EK280
Application Manual
108
7.3.3.5 Additional information: Cable occupation of the RJ45 network plug
7.3.4 EM260 with GSM-Modem
Initial conditions:
−
The EM260 is connected as described in
. It is connected but it must not be live.
7.3.4.1 Parameterization of the EK280 for operation with an EM260/GSM
i
For parameterization of the EK280 you need a connection cable for the optical interface as well
as the enSuite program. enSuite can be downloaded free of charge from the Honeywell website
in the "Software Downloads" section:
www.elster-instromet.com/en/software-downloads
a) Closing the time windows
−
In order that the parameterization works correctly the time windows 5 and 6 must be closed. Proceed
as described in
7.3.2.1 Parameterization of EK280 for operation with an EM260/analog
(p. 101).
b) Sending parameter file
−
Send the following parameter file to the EK280 (
EK280_xvx.. - EM260 & M2106 int. GSM (*)
−
For any further individual settings and tests required, press "
Navigation
" on the left-hand side and
then "
Parameterize online
" at the bottom of the navigation window.
i
All the values listed in enSuite under "
Parameters
" can be found on the “
Serv.
" display tab of the
EK280 under the same path.
i
The EK280 will only work with an EM260 model from year 2009 with a Baud rate of 19200.
EM260 devices before 2009 need to be operated with a Baud rate of 9600.
16
The "x" stands for the version of software on the device, e.g. "2v5".
The star * stands for a small letter which indicates the version of the file, e.g. "a".
Pinout