182
Figure 7- 51 Abnormity Setup Menu
Please refer to the following sheet for detailed information.
Parameter Function
Event
Type
z
The abnormal events include: no disk, no space, disk error, net error.
z
You need to draw a circle to enable this function.
Normal
Out
The corresponding alarm activation output channel when alarm occurs,
There are six channels.
Latch
The alarm output can delay for the specified time after alarm stops.
Then system disables alarm and corresponding activation output.
The value ranges from 10s to 300s.
Send
email
If you enable this function, system can send out email to alarm the
specified user.
Alarm
upload
System can upload the alarm signal to the network (includes the alarm
centre.)
Show
message
System pops up the alarm messages in the monitor interface.
Buzzer
Once you check the box here, the buzzer beeps when an alarm
occurred.
Video Matrix