Cleaning plan
Observe the operating instructions
W
orking steps
Detergent
Pr
ocess
Cleaning unit
Note
(1)
Preparatory
close cutting thick-
ness;
pull the mains
plug
(2)
Dismounting of
according to the
the removable
operating instructions
parts
(3)
Rough cleaning
remove the
plastic scraper
start directly after
product remainders
plastic spatula
knife end, also
manual
in case of
removable parts
(4)
Cleaning
P3 topax 56
after thorough
brush, tub,
all dismounted
RAN fat solvent
rinsing with water
cleaning cloth
and fi
xed
Pril with disinfectant
(max. 40° Celsius)
hand spray
machine parts
( see point 1 )
reaction time
see page 13
abt. 20 minutes
4.1
Din infection -
P3 alcodes
manual
disposable cleaning
additional
additional measure
(see point 2)
spray
cloth, manual spray
protection;
spray distance
abt. 30 cm
(5)
Rinsing
drinking water
temperature
disposable cleaning
other removed
max. 40° Celsius
cloth, hand spray
machine parts,
see page 13 f
f.
(6)
Checking
visually for optical
cleanliness
(7)
Drying
rub dry
disposable cleaning
machine,
dry in air
cloth
dismounted parts
(8)
Care
food oils
apply
disposable cleaning
rinse parts in contact
with
spray
cloth, manual spray
with product to be cut
H1 approval
prior to work
e.g. H Henkel P3
service oil
see page 15
(9)
Assembly
in reverse sequence
staf
f needs clean
to
and disinfected
disassembly
hands
(operating instructions)
(10)
Safety
cover machine when
measures
cleaning surrounding
area with spray guns
The data refer to a single-shift operation.
The safety and product data sheets supplied with the deter
gents and disinfectants have to be observed
(1)
P6 (phosphoric acid) - manufactur
er: Henkel, Düsseldorf, Germany
Concentration:
3% solution !!! Important !!! Observe mixture !
e.g. 20 litres = 300 ml P3 topax 56 (at 45° Celsius according to the instruc
tions of the manufacturer)
60