7. Electrical Installations 95
Error
code
Error name
Causes
To eliminate
05
On-board vol
-
tage too low
Electrical devices that consume
a great deal of energy reduce the
total output.
Charge the battery and connect the 230V mains connection.
Possibly switch off those devices (such as electric heating elements)
that consume a great deal of energy.
07
No search trans
-
ponder available.
Incorrect or manually modified
channel list
Have the correct list installed. Your dealer can do this.
Should these errors occur, the codes will appear in the display on the Kathrein control system. Please note that due, to these errors, the satellite
dish may in some cases switch itself off to prevent damage to the device. If possible, remove the source of trouble before restarting the system.
Never attempt to open or modify the equipment - this must be done by an authorised Hobby dealer!
Problem
Cause
Solution
Long search times
The system is searching in the
wrong region.
Set the region in which the mobile home is located (see Chap. 7,
submenu: Set position).
Satellite not found/ no
reception
The mobile home is located out
-
side the satellite’s footprint.
Select another satellite.
Uncontrolled performance
of the turnable satellite
dish
The turnable satellite dish has
“lost” the satellite and cannot find
it again.
Reset the system. The reset button is located on the back of the
CAP 650.
These problems are not errors that will cause the system to stop and send an error message. Therefore, they have no error code.
Summary of Contents for Vantana 2018
Page 1: ...MANUAL Version 11 2017 Van Vantana GB...
Page 206: ...14 Technical Data 205 Index...