Chapter 2 Installation and Wiring
2 - 20
(4) Connecting a programmable controller to intelligent input terminals
When using the internal interface power supply
When using an external power supply
(Remove the jumper from the control circuit terminal block.)
Sink logi
c
Source logi
c
(5) Connecting a programmable controller to intelligent output terminals
Sink logi
c
Source logi
c
2.2.4 Wiring of the digital operator
- You can operate the inverter with not only the digital operator mounted in the inverter as standard
equipment but also an optional digital operator (OPE-S, OPE-SR, SRW-OJ, or SRW-OEX).
- When you intend to remove the standard digital operator from the inverter and use it as remote
equipment, request your local Hitachi Distributor to supply a connection cable, ICS-1 (1-meter cable) or
ICS-3 (3-meter cable).
If you prepare the cable by yourself, the following product is recommended:
HUTP5 PC 4P -X-X: Straight cable equipped with connector at both ends (made by Hitachi Cable, Ltd.)
- The length of the connection cable must be 3 m or less. If a cable over 3 m is used, the inverter may
malfunction.
Inverter
Output module
(EH-YT**,etc.)
Jumper
S
COM
P24
PLC
CM1
FW
8
Inverter
P24
DC24V
CM1
FW
DC24V
S
COM
Output module
(EH-YTP**,etc.)
8
Inverter
Output module
(EH-YTP**,etc.)
DC24V
DC24V
COM
S
P24
PLC
CM1
FW
8
DC24V
Inverter
Output module
(EH-YT**,etc.)
S
COM
P24
PLC
CM1
FW
8
Jumper
11
12
CM2
COM
Inverter
XDC24D2H
DC24V
Inverter
11
XDC24D2H
12
CM2
COM
DC24V
DC24V
PLC