Chapter 2 Installation and Wiring
2 - 10
Note: If the data of an optional operator (SRW or SRW-EX) is copied:
If operator data is copied to your SJ700B series inverter whose slide switch SW1 is ON from another SJ700B series
inverter whose slide switch SW1 is OFF, the digital operator on your SJ700B series inverter may display [R-ERROR
COPY ROM] for a moment. This event may occur because the data on intelligent input terminals [1] and [3] cannot be
copied since, on your inverter, exclusive functions have already been assigned to intelligent input terminals [1] and [3]
due to the slide switch SW1 setting to ON. Note that other data is copied. If this event occurs, check the settings on
both copy-source and copy-destination inverters.
Note: Slide Switch 12
Some models have slide switch in the position as shown below. Default setting of this switch is at "ON" position.
Please don't change the setting. If it is changed, inverter may trip and disabled to run.
ON
Slide switch SW1
OFF
ON
Slide lever (factory setting: OFF)
Logic board
ON
OFF
ON
Slide lever
(factory setting: ON)
Slide switch SW12