Chapter 2 Installation and Wiring
2 - 13
(2) Layout of main circuit terminals
The figures below show the terminal layout on the main circuit terminal block of the inverter.
Terminal layout
Inverter model
SJ700B-055HEF
R0 and T0:M4
Ground terminal:M4
Other terminal:M4
[Method of enabling/disabling the EMC filter function]
R
(L1)
S
(L2)
T
(L3)
PD
(+1)
P
(+)
N
(-)
U
(T1)
V
(T2)
W
(T3)
R0
T0
charge lump
Jumper connecting
Terminals PD and P
G
G
RB
To activate EMC filter, please
configure the setting with the
filter activate pin (J61) and
deactivate pin (J62) as indicated
below table.
Please make sure tha the power
is off before modifying the
setting. There is a danger of
electrical shock..
Pleasse be sure to operate the
inverter with the plugs inserted
properly.
Short plug
Dummy plug(green)
Selector pin(J61)
Selector pin (J62)
selector pin(J61)
selector pin (J62)
Enabling the EMC filter
(factory setting:xFEF2)
Short plug
Dummy plug(green)
Disabling the EMC filter
(factory setting:xFF2,xFUF2)
Dummy plug(green)
Short plug