Chapter 4 Explanation of Functions
Function code
Data
Description
Reference item
Page
51 F-TM:
Forcible-terminal
operation
Forcible-terminal operation function
4-51
52
ATR: Permission of torque command input
Torque control function
4-98
53
KHC: Cumulative power clearance
Cumulative power monitoring function
4-4
54
SON: Servo On
Servo on function
4-111
55
FOC: Forcing
forcing function
4-91
56
MI1: General-purpose input 1
57
MI2: General-purpose input 2
58
MI3: General-purpose input 3
59
MI4: General-purpose input 4
60
MI5: General-purpose input 5
61
MI6: General-purpose input 6
62
MI7: General-purpose input 7
63
MI8: General-purpose input 8
Easy sequence function (*1)
-
65
AHD: Analog command holding
Analog command holding function
4-59
66
CP1: multistage position settings selection 1
67
CP2: multistage position settings selection 2
68
CP3: multistage position settings selection 3
4-108
69
ORL: Zero-return limit function
70
ORG: Zero-return trigger function
4-109
71
FOT: forward drive stop
72
ROT: reverse drive stop
4-110
73
SPD: speed / position switching
Absolute position control mode
4-108
74
PCNT: pulse counter
C001 to C008
75
PCC: pulse counter clear
Intelligent pulse counter
4-59
(*1) Refer to programing software EZ-SQ user manual.
4.2.39 Input terminal a/b (NO/NC) selection
C011 to C018: Terminal [1] to [8] active state
C019: Terminal [FW] active state
Related code
The input terminal a/b (NO/NC) selection function allows you to
specify a-contact or b-contact input for each of the intelligent
input terminals [1] to [8] and the FW terminal.
An a-contact turns on the input signal when closed and turns it off when opened.
An b-contact turns on the input signal when opened and turns it off when closed.
The terminal to which the reset (RS) function is assigned functions only as an a-contact.
Item Function
code
Data
Description
00 a-contact
(NO)
Terminal active state
C011 to C018
01 b-contact
(NC)
00 a-contact
(NO)
Terminal [FW] active state
C019
01 b-contact
(NC)
4.2.40 Multispeed select setting (CF1 to CF4 and SF1 to SF7)
A019: Multispeed operation selection
A020/A220/A320: Multispeed frequency
setting, 1st/2nd/3rd motors
A021 to A035: Multispeed 1 to 15 settings
C001 to C008: Terminal [1] to [8] functions
C169: Multistage speed/position determination
time
Related code
The multispeed select setting function allows you to set multiple
motor speeds and switch among them by way of signal input
via specified terminals.
Multispeed operation can be performed in two modes: binary
operation mode (with up to 16 speeds) using four input
terminals and bit operation mode (with up to eight speeds)
using seven input terminals.
Item Function
code
Data
Description
00
Binary operation mode with up to 16 speeds
Multispeed
operation selection
A019
01
Bit operation mode with up to 8 speeds
Multispeed 0 to 15
settings
A020/A220/
A320
A021 to A035
0.00 or "start frequency" to
"maximum frequency" (Hz)
Setting of the frequency as each speed
Carefully note that during multispeed operation, the rotation direction specified in an operation command is
reversed if the sum of the frequencies specified by the main frequency and auxiliary frequency commands
is less than 0 Hz when the following settings have been made:
- The control circuit terminal block (01) is specified for the frequency source setting (A001).
- The external analog input (O/O2/OI) mode, set by a combination of [AT] selection (A005), [O2] selection
(A006), and AT terminal On/Off state allows reversible motor operation.
4 -
47
Summary of Contents for SJ700-055HFF2
Page 15: ...Contents xiii Appendix Appendix A 1 Index Index Index 1 ...
Page 17: ......
Page 22: ......
Page 43: ...Chapter 2 Installation and Wiring 2 21 ...
Page 48: ......
Page 51: ...Chapter 3 Operation 3 3 ...
Page 63: ......
Page 152: ...Chapter 4 Explanation of Functions 4 89 H034 H234 ...
Page 161: ...Chapter 4 Explanation of Functions 4 98 ...
Page 219: ...Chapter 4 Explanation of Functions 4 156 ...
Page 232: ......
Page 244: ......
Page 252: ......
Page 258: ...Chapter 7 Specifications SJ700 550 LFF2 LFUF2 5 Cable hole φ41 7 6 ...
Page 260: ......