Chapter 5 Error Codes
5.2 Warning Codes
The following table lists the warning codes and the contents of parameter readjustments:
Warning code
Target function code
Condition
Basic function code
001/ 201
Frequency upper limit setting (A061/A261)
>
002/ 202
Frequency lower limit setting (A062/A262)
>
004/ 204/ 304 Base frequency setting (A003/A203/A303) (*1)
>
005/ 205/ 305
Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)
>
006/ 206/ 306 Multispeed 1 to 15 settings (A021 to A035)
>
009
Home search speed setting (P015)
>
Maximum frequency setting
(A004/A204/A304)
012/ 212
Fequency lower limit setting (A062/A262)
>
015/ 215
Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)
>
016/ 216
Multispeed 1 to 15 settings (A021 to A035)
>
Frequency upper limit setting
(A061/A261)
019
<
Home search speed setting
(P015)
021/ 221
Frequency upper limit setting (A061/A261)
<
025/ 225
Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)
<
Fequency lower limit setting
(A062/A262)
031/ 231
Frequency upper limit setting (A061/A261)
<
032/ 232
Fequency lower limit setting (A062/A262)
<
035/ 235/ 335 Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)
<
036
Multispeed 1 to 15 settings (A021 to A035)
<
037
Jog frequency setting (A038)
<
Start frequency adjustment (b082)
085/ 285/ 385
Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)
<>
086
Multispeed 1 to 15 settings (A021 to A035)
<>
Jump (center) frequency settings
1/2/3 ± " Jump (hysteresis)
frequency width settings 1/2/3"
A063 ± A064, A065 ± A066,
A067 ± A068 (*3)
091/ 291
Frequency upper limit setting (A061/A261)
>
092/ 292
Fequency lower limit setting (A062/A262)
>
095/ 295
Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)
>
096
Multispeed 1 to 15 settings (A021 to A035)
>
Free-setting V/f frequency (1) to (6) (b100, b102, b104, b106,
b108, b110)
>
Free-setting V/f frequency (7)
(b112)
Free-setting V/f frequency (2) to (6) (b102, b104, b106, b108,
b110)
<
Free-setting V/f frequency (1)
(b100)
Free-setting V/f frequency (1) (b100)
>
Free-setting V/f frequency (3) to (6) (b104, b106, b108, b110)
<
Free-setting V/f frequency (2)
(b102)
Free-setting V/f frequency (1) (2) (b100, b102)
>
Free-setting V/f frequency (4) to (6) (b106, b108, b110)
<
Free-setting V/f frequency (3)
(b104)
Free-setting V/f frequency (1) to (3) (b100, b102, b104, b110)
>
Free-setting V/f frequency (5) (6) (b108, b110)
<
Free-setting V/f frequency (4)
(b106)
Free-setting V/f frequency (1) to (4) (b100, b102, b104, b106)
>
Free-setting V/f frequency (6) (b110)
<
Free-setting V/f frequency (5)
(b108)
110
Free-setting V/f frequency (1) to (5) (b100, b102, b104, b106,
b108)
>
Free-setting V/f frequency (6)
(b110)
Free setting, electronic thermal frequency (2) (3) (b017/b019)
<
Free setting, electronic thermal
frequency (1) (b015)
Free setting, electronic thermal frequency (1) (b015)
>
Free setting, electronic thermal frequency (3) (b019)
<
Free setting, electronic thermal
frequency (2) (b017)
120
Free setting, electronic thermal frequency (1) (2) (b015/b017)
>
Free setting, electronic thermal
frequency (3) (b019)
The inverter displays a warning code when the data set as a target function code satisfies the condition (specified in
the Condition column) in relation to the data set as the corresponding basic function code.
Each parameter (target function code) is readjusted to the data set as the basic function code (by updating at the
inverter start-up).
*1 In this case, the base frequency is rewritten at parameter readjustment. If the base frequency is updated to an
inappropriate value, a motor burnout may result. Therefore, if the warning is displayed, change the current base
frequency data to an appropriate value.
*2 These parameters are checked, even when the digital operator (02) is not specified for the frequency source
setting (A001).
*3 The current value of the jump (center) frequency is updated to "'the current value of the jump frequency' - 'value of
the Jump (hysteresis) frequency width (minimum)'".
5 - 10
Summary of Contents for SJ700-055HFF2
Page 15: ...Contents xiii Appendix Appendix A 1 Index Index Index 1 ...
Page 17: ......
Page 22: ......
Page 43: ...Chapter 2 Installation and Wiring 2 21 ...
Page 48: ......
Page 51: ...Chapter 3 Operation 3 3 ...
Page 63: ......
Page 152: ...Chapter 4 Explanation of Functions 4 89 H034 H234 ...
Page 161: ...Chapter 4 Explanation of Functions 4 98 ...
Page 219: ...Chapter 4 Explanation of Functions 4 156 ...
Page 232: ......
Page 244: ......
Page 252: ......
Page 258: ...Chapter 7 Specifications SJ700 550 LFF2 LFUF2 5 Cable hole φ41 7 6 ...
Page 260: ......