752
Bits 2 to 0—Channel Select 2 to 0 (CH2 to CH0): Together with the SCAN bit, these bits select
the analog input channels.
Only set the input channel while conversion is stopped (ADST = 0).
Channel Selection
Description
CH3
CH2
CH1
CH0
Single Mode
(SCAN = 0)
Scan Mode
(SCAN = 1)
0
0
0
0
AN0 (Initial value)
AN0
1
AN1
AN0, AN1
1
0
AN2
AN0 to AN2
1
AN3
AN0 to AN3
1
0
0
AN4
AN4
1
AN5
AN4, AN5
1
0
AN6
AN4 to AN6
1
AN7
AN4 to AN7
1
0
0
0
AN8
AN8
1
AN9
AN8, AN9
1
0
AN10
AN8 to AN10
1
AN11
AN8 to AN11
1
0
0
AN12
AN12
1
AN13
AN12, AN13
1
0
AN14
AN12 to AN14
1
AN15
AN12 to AN15