5 - 19
Disassembly and Reassembly > Disassembly
;%=83ILVER
%=
;%=
D
C
B
A
0ULLOUT
5NLOCK
Fig. 5-3-16
1) Disconnect the
fl
at cable from EXL circuit board (a).
2) Remove the two screws [E], taking care not to lose the LCD ground plate (b), which will be de-
tached at this time.
(a) EXL circuit board
(b) LCD ground plate
(c) LCD unit
(d) L case
(16) LCD Unit
Note:
Take great care when handling the LCD unit.
The LCD unit has an LCD panel that is a precision component: Subjecting it to any impact could
result in a fault.