5.10 Developing application programs
Application programming is performed by using this product. In addition to Linux standard development software,
CE50-10 has an SDK to which various libraries for using unique functions are added.
5.10.1 Development environment hardware configurations
(1) Hardware configuration No. 1
A personal computer (PC) is connected to the unit as a human-machine interface device.
Table 5‒7: Device connected to the unit in configuration No. 1
Device
Connection interface
Description
Personal computer
(PC)
Ethernet
This device is used for the operation of data backup, data restore, and
program update functions.
Connect the PC to the development unit by using an Ethernet crossover
cable.
Figure 5‒9: Configuration for connecting the PC
(2) Hardware configuration No. 2
A display, a keyboard, and a USB flash drive are connected to the unit as an HMI.
Table 5‒8: Devices connected to the unit in configuration No. 2
Device
Connection interface
Description
Keyboard
USB
This device is used for the operation of data backup, data restore,
and program update functions.
Display
DisplayPort
Console screen
USB flash drive
USB
External media that stores backup data
5. Configuring Software Environment
52
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...