5.9 Changing the operation to be performed in the case
of a disk fault
If a disk fault occurs during the operation of the unit or if a slowdown in the disk access time is detected, a kernel
panic occurs by default. If you want to change this setting so that operation of the unit continues after a disk fault or a
slowdown detection, you need to change the definition file settings.
Definition files
•
Definition file for disk faults: /
hitachi/etc/dskptrl_stop.conf
•
Definition file for slowdown detection:
/hitachi/etc/slowdown_stop.conf
Item specified in a definition file
stop
definition-value
--- (A)
(A)
Specify
0
or
1
. The default is
0
. To change the operation, change the setting to
1
.
Table 5‒6: Definition values of the stop item
Definition value
Description
0
A kernel panic (default setting) occurs.
1
Unit operation continues.
5. Configuring Software Environment
51
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...