Run the
rxversion
command to check the device file names and OS versions for the active area and inactive
area (see the
bold underlined parts
).
$ sudo rxversion
<Inactive>(/dev/sda2)
CTRL-EDGEN-IMG
model-name
version-information
<Active><Running>(/dev/sda3)
CTRL-EDGEN-IMG
model-name
version-information
<BIOS>
version-information
<RAS MCU F/W>
<version information>
<TPM>
<version information>
$
6. Run the OS update command.
Run the
ecosupdate
command to update the OS in the inactive area and switch the system area that will be the
active area the next time the unit starts to the area containing the updated OS.
$ sudo ecosupdate /mnt/osupdate
7. Check the OS version and partition of the active area to be started next.
Run the
rxosenable
command with the
-p
(next startup area display) option specified. Then, confirm that the
partition to be started next has changed to the current inactive area, and the OS version of that inactive area is
updated (see the
bold underlined parts
).
$ sudo rxosenable -p
OS(
version-number
) is enabled. (
/dev/sda2
)
8. Unmount the external media from the unit.
After restoration finishes, unmount the connected external media from the unit.
$ sudo umount /mnt/osupdate
9. Remove the external media from the unit.
10. Reboot the unit.
$ sudo reboot
11. (No user operation required) Automatically log out from the unit.
Wait for the system to start.
12. Check the communication between the maintenance PC and the unit.
Run the
ping
command to confirm that the maintenance PC can communicate with the unit.
$ ping
IP-address-of-the-target-unit
13. Remotely log in to the unit from the maintenance PC.
Remotely log in to the unit.
Example user name:
edgeadm
login: edgeadm
Password: *******
14. Run the version display command to check the OS versions of the active area and inactive area.
Run the
showecmode
command to confirm that the OS operation mode is
Normal
mode
(see the
bold
underlined parts
).
$ sudo showecmode
Current :
Normal mode
Next :
Normal mode
$
Then, run the
rxversion
command to check the device file names and OS versions for the active area and
inactive area (see the
underlined parts
). In this example, confirm that the device file name of the active area
is
/dev/sda2
.
5. Configuring Software Environment
94
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...