$ sudo ecmodeset -enable
Set next boot: Maintenance mode
$
The following is displayed when normal mode is set as the next OS start mode.
$ sudo ecmodeset -disable
Set next boot: Normal mode
$
<Diagnosis>
For the exit code,
0
is returned if the status is normal and
1
is returned if an error is detected. Table 5‒24: List of
Table 5‒24: List of ecmodeset command error messages
No.
Error message
Description
1
Usage: ecmodeset [ -enable | -
disable ]
The specified argument is invalid.
2
Failed to set next boot:
Maintenance mode
An attempt to set maintenance mode failed.
3
Failed to set next boot:
Normal mode
An attempt to set normal mode failed.
5.18.2 showecmode
<Name>
showecmode
- Display the OS operation mode.
<Format>
showecmode
<Description>
This command displays the current OS startup mode and the next OS startup mode.
<Display format>
Current :
OS-startup-mode
Next :
OS-startup-mode
Notes
•
If normal mode is set,
Normal
mode
is displayed.
•
If maintenance mode is set,
Maintenance
mode
is displayed.
If an attempt to collect information failed,
Unknown
is displayed. If
Unknown
is displayed, a fault is likely
to exist in the SSD. In this case, replace the unit.
<Options>
No options need to be specified. Any specified options are ignored.
<Display example>
The command displays the current OS startup mode and the next OS startup mode.
The following shows an example of when the current mode is maintenance mode and the next startup mode is
normal mode.
$ sudo showecmode
Current : Normal mode
Next : Maintenance mode
$
<Diagnosis>
For the exit code,
0
is returned if the status is normal and
1
is returned if an error is detected.
An error message is not output.
5. Configuring Software Environment
106
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...