4.1 PSDOWN (EXT)
4.1.1 Signal name
PSDOWN, DO0_GND
4.1.2 Description
Power-off signals.
These signals indicate that power to the target unit is turned off.
4.1.3 Specifications
Table 4‒1: PSDOWN contact specifications
I/O
Item
Specifications
Output specifications
Output method
Photo-MOS relay contact (Form B contact)
Load voltage
Max. 40 V DC (external power supply required)
Load current
Steady state: Max. 0.1 A/point
Dielectric strength
250 V AC, 1 minute
4.1.4 Terminal number
Table 4‒2: PSDOWN terminal number
Signal
Terminal number
PSDOWN
14
DO0_GND
2, 5, 15
4.1.5 Connection diagram
Figure 4‒1: Connection diagram
4. External Contact Functions
24
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...