3.2 Making Settings on the Logger
31
3
3
Chapter 3 Set
tings
To return to the Measurement display from any Settings display, press the
REC/
STOP
button.
3.2
Making Settings on the Logger
• When the
battery indicator appears, settings cannot be changed
(although they can still be displayed).
• When no operation occurs for 30 seconds with Settings displayed,
automatically switches to Measurement display.
• Settings cannot be changed while recording. However, settings can
still be displayed by pressing the
SET
button from the Measurement
display.
Recording Interval Setting
1
Press the
SET
button to display the inter-
val setting.
(The
[INTVL]
indicator appears,
and the setting blinks.)
2
Press the
(+)
and
(-)
buttons to change
the recording interval.
Example of configuration:
1sec 00:01, 1 minute 01:00
3
Press the
SET
button to accept the setting.
(The year setting is displayed.)
Recording Interval
1(Default)/2/5/10/15/20/30 sec., 1/2 /5/10/15/20/30/60 min