75
Auto-hold Function
6.2 Auto-hold Function
This function automatically recognizes the stability of measurement
values and retains them.
Press the
A HOLD/MEMO
key several times to display
[A.HOLD]
.
Auto-hold
Auto-memory
OFF
Auto-hold and
Auto-memory
To cancel the retaining, press the
HOLD
key or the
PRESS
button
on the model 9466 Remote Control Switch.
When resistance is displayed as
[
íííí
]
, data is not retained
automatically.
Data will not be retained automatically when
[OVER]
and the
PD[LPXPGLVSOD\YDOXHRIWKHUHVLVWDQFHDUHÀDVKLQJ
The instrument retains and stores measurement values
automatically when the auto-memory function is used together
with this function.
Use the auto-hold function together with the comparator
function to determine if
[OVER]
(and the maximum display
YDOXHLVÀDVKLQJGXHWRDUDQJHVHWWLQJHUURU6HWWLQJWKH
comparator buzzer to
[FAIL]
is also recommended. For more
information, see “4.4 Setting the Comparator Buzzer” (p. 63).