WEB Configuration of DS-3E2300P Series Ethernet SwitchEW
[
选取日期
]
46
If the alarm type is absolute, the value of the MIB object will be directly minitored; if the
alarm type is delta, the change of the value of the MIB object in two sampling will be
monitored.
When the monitored MIB object reaches or exceeds the rising threshold, the event
corresponding to the index of the rising event will be triggered.
When the monitored MIB object reaches or exceeds the falling threshold, the event
corresponding to the index of the falling event will be triggered.
8.2.4 RMON Event Configuration
Click Network Management Config -> RMON -> RMON Event -> New, the RMON event
page appears.
The index corresponds to the rising event index and the falling event index that have
already been configured on the RMON alarm config page.
The owner is used to describe the descriptive information of an event.
"Enable log" means to add an item of information in the log table when the event is
triggered.
“Enable trap” means a trap will be generated if the event is triggered.