8.3.1.4 Environmental Requirements
Relative Humidity
0% – 90%, non-condensing
Temperature (Operating)
0º – 50º C (32º – 122º F)
Temperature (Storage)
-20º – 70º C (-4º – 158º F)
Mounting Requirements
Display must be mounted in a dry area. Direct sunlight should be avoided.
8.3.1.5 Shock & Vibration
Normal automotive environment. The display should not be dropped.
8.3.1.6 Electrical Specifications
All electrical power is provided by the COMPUSHIFT II controller
Connection is provided via a standard 4-pin connector and 2 meter (6 foot) cable.
Custom cable lengths available upon request
8.3.1.7 Display Formats
Mixed display of information in small characters
Large digits
Bar graphs
8.3.1.8 Running Dashboard Displays
The display provides a number of meters while the system is operating, including:
System Status and Diagnostics
Vehicle Speed
Engine Speed
Current Gear
Throttle Position
Relative Hydraulic Pressure
Transmission Temperature
System Voltage
Dynamometer
Accelerometer
Stopwatch with Lap Times
Data Log
8.3.1.9 On-the-fly adjustments
Shift Pressure
Shift Speed