9600
◦
19200
◦
57600
◦
115200
For correct operation, set the serial port configuration to no parity, 8 data bits, and 1 stop bit (N/8/1).
NOTE:
The 38400 speed is supported in the iLO web interface, but is not currently supported by the
iLO 5 Configuration Utility.
•
iLO Web Interface
—Specifies whether the iLO web interface can be used to communicate with iLO.
This setting is enabled by default.
Configuring access settings
Procedure
1.
From the
System Utilities
screen, select
System Configuration
>
iLO 5 Configuration Utility
>
Setting Options
.
2.
Update user access
.
3.
Save your settings.
Set to factory defaults
CAUTION:
This operation clears all user and license data.
Use this option to reset iLO to the factory default settings. When you do so, you cannot access the iLO 5
Configuration Utility until after the next system reboot. If you are managing iLO remotely, the remote
console session is automatically ended.
If the server has a factory installed license key, the license key is retained.
Resetting iLO to the factory default settings
Procedure
1.
From the
System Utilities
screen, select
System Configuration
>
iLO 5 Configuration Utility
>
Set
to factory defaults
.
The iLO 5 Configuration Utility prompts you to select
YES
or
NO
.
2.
Select
YES
.
3.
When prompted to confirm the reset, press
Enter
.
iLO resets to the factory default settings. If you are managing iLO remotely, the remote console
session is automatically ended.
4.
Resume the boot process:
a.
Optional: If you are managing iLO remotely, wait for the iLO reset to finish, and then start the iLO
remote console.