Host CPLD Version
—The server complex programmable logic device version.
•
Serial Number
—The iLO serial number.
•
PCI BUS
—The PCI bus to which the iLO processer is attached.
•
Device
—The device number assigned to iLO in the PCI bus.
Viewing information about iLO
Procedure
1.
From the
System Utilities
screen, select
System Configuration
>
iLO 5 Configuration Utility
>
About
.
2.
View information
Viewing and configuring embedded device information
NIC and FCoE information
The
System Configuration
screens show information about and configure installed system devices,
such as embedded NICs and FCoEs. Devices listed and configuration options available vary by system.
Viewing and configuring NIC and FCoE settings
Use the
System Configuration
screens to view information about and configure installed system
devices, such as embedded NICs and FCoEs. Devices listed and configuration options available vary by
system.
Procedure
1.
From the
System Utilities
screen, select
System Configuration
.
2.
Select a device.
A
System Configuration
screen displays information about the embedded device.
3.
View, select, or enter settings.
4.
Save your settings.
NPAR configuration
NPAR (NIC Partitioning multi-function mode) enables you to partition a NIC into multiple virtual NICs with
multiple PCI physical functions per port. Each PCI function is associated with a different virtual NIC. To
the OS and the network, each physical function appears as a separate NIC port.
Enabling NPAR on a NIC
NOTE:
The following procedure shows how to enable NPAR on an
Embedded FlexibleLOM
card. NIC
options vary by system.
Procedure
1.
From the
System Configuration
screen, select an
Embedded FlexibleLOM
and press
Enter
.
System Configuration
25