35
Hwang Sun Enterprise Co., Ltd.
35 Edition 2012/02
The filter of the manifold is
blocked.
The nozzle assembly is blocked
with charring.
The heater hose is blocked with
charring.
Clean the filter.
Reset the proper operating
temperature of the nozzle
assembly or leave for the
qualify personnel to clean
and disassemble the nozzle.
Adjust the operation
temperature of the hose and
clean the hose.
5.3 TROUBLESHOOTING FOR ADHESIVE APPLICATION PROBLEMS
PROBLEM
POSSIBLE CAUSES
CORRECTIVE ACTION
Excessive adhesive at
beginning of bead
deposit
1.Too much pressure to the gear
pump.
2. Nozzle is too far from the
substrate.
3. The nozzle partially plugged.
Adjust the pressure of
pressure regulator or the
inverter, to reduce the
motor speed.
Move nozzle to the
distance of 0.5
〞
(12.7mm)
from substrate.
Dismantle the nozzle and
clean it.
Excessive adhesive at
the end of bead deposit.
1. Insufficient pressure to gear
pump.
2. The adhesive is too cold.
3. Too long nozzle or low
temperature.
Adjust the pressure of
pressure regulator or the
inverter, to increase the
motor speed.
Adjust properly the
temperatures of all heating
zones.
Adjust the operation
temperature of nozzle
assembly or change the
nozzle of right length.
Summary of Contents for HS2510-N
Page 1: ...Hwang Sun Enterprise Co Ltd 0 Edition 2012 02 00 ...
Page 19: ...17 Hwang Sun Enterprise Co Ltd 17 Edition 2012 02 3 2 INSTRUCTIONS OF OPERATION PANEL ...
Page 50: ...48 Hwang Sun Enterprise Co Ltd 48 Edition 2012 02 FIGURE 6 1 5 MANIFOLD ASSEMBLY ...
Page 52: ...50 Hwang Sun Enterprise Co Ltd 50 Edition 2012 02 FIGURE 6 1 6 BY PASS VLAVE ...
Page 54: ...52 Hwang Sun Enterprise Co Ltd 52 Edition 2012 02 FIGURE 6 1 7 FILTER ASSEMBLY ...
Page 56: ...54 Hwang Sun Enterprise Co Ltd 54 Edition 2012 02 FIGURE 6 1 8 WIRING DIAGRAM ...
Page 57: ...55 Hwang Sun Enterprise Co Ltd 55 Edition 2012 02 FIGURE 6 1 9 WIRING DIAGRAM ...
Page 58: ...56 Hwang Sun Enterprise Co Ltd 56 Edition 2012 02 FIGURE 6 1 10 WIRING DIAGRAM ...
Page 62: ...60 Hwang Sun Enterprise Co Ltd 60 Edition 2012 02 FIGURE 6 1 14 PARAMETER SETTING OF INVERTER ...