11
Hwang Sun Enterprise Co., Ltd.
11 Edition 2012/02
OC
Over-current
during stop
1. Detection circuit malfunctions
2. Bad connection for CT
signal cable
1.Check the noise between Power
line and motor line
2. Send the inverter back for
repairing
OL1
Motor overload
1. Heavy load
2. Inappropriate settings of
0-02, 9-08~11
1. Increase the motor capacity
2. set 0-02, 9-08~11 properly
OL2
Inverter
overload
Heavy Load
Increase the inverter capacity
OL3
Over torque
1. Heavy Load
2. Insufficient settings of 9-14,
9-15
1. Increase the inverter capacity
2. set 9-14, 9-15 properly
2.3.2 Hydraulic System
1. Melting Tank
The adhesive is melted by heaters in Teflon–coated tank, in order to avoid
adhesive inside tank getting charred on the wall and change adhesive inside tank
easily. There are some fins set in the internal wall of tank to increase melting rate.
Temperature control is accomplished by means of the k-type (RTD) sensor
mounted at the bottom of the tank, to detect the temperature and transfer into
signal to pass to temperature controller.
2.Gear Pump
The gear pump of HS2510-N applicator is installed at the bottom of the tank,
which be driven by the 3 phase motor, through gear and chain to drive the
driver shaft of this gear pump, and the speed-alteration of the gear pump is
controlled by an inverter as shown on figure 2.6.
While the gear of the driver shaft rotate as the clockwise to drive the gear
which meshed with it, so the hot adhesive of inlet(glue flowing in) will be
pressed by gear and flow to the manifold. Then due to the atmospheric
pressure and the section produced by the rotary gear pump the hot adhesive in
the tank will be replenished to inlet (glue flowing in).
All gears in this system are spur gears.
Summary of Contents for HS2510-N
Page 1: ...Hwang Sun Enterprise Co Ltd 0 Edition 2012 02 00 ...
Page 19: ...17 Hwang Sun Enterprise Co Ltd 17 Edition 2012 02 3 2 INSTRUCTIONS OF OPERATION PANEL ...
Page 50: ...48 Hwang Sun Enterprise Co Ltd 48 Edition 2012 02 FIGURE 6 1 5 MANIFOLD ASSEMBLY ...
Page 52: ...50 Hwang Sun Enterprise Co Ltd 50 Edition 2012 02 FIGURE 6 1 6 BY PASS VLAVE ...
Page 54: ...52 Hwang Sun Enterprise Co Ltd 52 Edition 2012 02 FIGURE 6 1 7 FILTER ASSEMBLY ...
Page 56: ...54 Hwang Sun Enterprise Co Ltd 54 Edition 2012 02 FIGURE 6 1 8 WIRING DIAGRAM ...
Page 57: ...55 Hwang Sun Enterprise Co Ltd 55 Edition 2012 02 FIGURE 6 1 9 WIRING DIAGRAM ...
Page 58: ...56 Hwang Sun Enterprise Co Ltd 56 Edition 2012 02 FIGURE 6 1 10 WIRING DIAGRAM ...
Page 62: ...60 Hwang Sun Enterprise Co Ltd 60 Edition 2012 02 FIGURE 6 1 14 PARAMETER SETTING OF INVERTER ...