6.2.3 Auto Mode
Overview
The auto mode is used to run a program, initialize the rotary dispense system’s home position
and purge the valve or syringe. When the rotary dispense station is in the auto mode, it will
display “Auto Mode” on the left side of the display and the program number in the upper right
hand side of the display.
Notice:
If “Repeat” is displayed to the right of “Auto”, the rotary dispense system is
actually in auto repeat mode. Please use caution as the unit will cycle continuously without input
from the operator in auto repeat mode.
Notice:
If it is desired to change the program number while in “Auto” mode, you must
enter the programming mode by pressing the mode button twice. If you are in “Auto Repeat”
Mode you will need to press the mode button three times to enter the programming mode.
Key Definition
MODE – to cycle between different modes. Pressing the button quickly in auto mode will bring
you to set up mode. Pressing the button for 2 seconds will bring you to auto repeat mode.
START – to run the current program. The program can also be initiated using a foot switch.
HOME - If the rotary dispense station is knocked out of position, it will be necessary to
initialize the system resetting its home position using this button.
PURG - can be used to dispense adhesive at any time. This will typically be used during set up
to set the adhesive dispense rate or to purge the unit during extended down times when using
reactive adhesives.