6.4.3 A Single Dot
Program Data:
Variables
Units
Value
# Events
1
Auto Repeat Time
Seconds
15.0
Start Position 1
Degrees
90.0
Timer A1
Seconds
0.50
End Position 1
Degrees
90.0
Timer B1
Seconds
0.25
Rotating Speed 1
RPM
25.0
Function timing diagram and illustration of dispense pattern:
90°
0°
Down
Up
Off
On
Dispense
Slide Position
Slew RPM
1
2
3
1. Slew RPM (Global)
2. Timer A
3. Timer B
90°
0°
31