1.
Insert the 5/32” tube x ¼” NPT fittings into the “DISPENSE ON” and “DISPENSE OFF”
connections on the back of the controller.
Notice:
When installing fittings be sure to hold the silver bulkhead fitting in the back of
the unit with one wrench and tighten the fitting being installed with a second wrench.
2.
Connect the “DISPENSE ON” and “DISPENSE OFF” from the valve to the back of the
controller using the 5/32” air line tubing supplied with the valve.
3.
Add the dispense tip to the valve.
4.
Slide the mounting bracket over the mounting rail on the slide assembly and secure it in position
with the white nylon thumbscrew.
5.
Manually pull the slide down to the fully extended position.
6.
Slide the valve into the mounting bracket and secure it using the black thumbscrews.
7.
Adjust the height and position of the mounting bracket to the approximate position desired. To
adjust the position, turn the handle on the clamp blocks counter clockwise, set the position and
secure by turning the handle clockwise.
Caution!
It is important to ensure that the dispense tip will not crash with the mounting
plate, fixture or part. Please ensure that the height is set to avoid crashes.
8.
Set the “POWER” switch to off (in the position marked “0”), the “DISPENSE PRESSURE” to
0 psi (turn the knob counter-clockwise until it stops) and the “VACUUM” off (turn the knob
clockwise until it stops).
9.
Reset the “EMERGENCY STOP” by rotating in either direction and pulling it out.
Warning!
When the emergency stop is reset, the slide may retract. Be sure to keep
your hands and other objects clear of the slide before resetting the emergency stop.
10.
The single rotary dispense station is now ready to be programmed.
4.3.4 983914, 986300 and 982621 Poppet Valves
Warning!
Before integrating any dispensing equipment, please press the “EMERGENCY
STOP” button. This will dump the pressure to all pneumatic devices and allow the slide to
advance eliminating the potential for pinch points. It will also allow the syringe, cartridge or
valve to be installed when the slide is advanced minimizing the potential for crashes.
Must be purchased separately:
•
Mounting bracket – P/N 98408
•
Pressure Reservoir
- P/N 982726, Bond-A-Matic reservoir, 0-15 psi for use with adhesives with <3,000 cP viscosity.
- P/N 982727, Bond-A-Matic reservoir, 0-100 psi for use with adhesives with >3,000 cP viscosity.
1.
Insert the 1/4” tube x ¼” NPT fittings into the “DISPENSE ON” and “DISPENSE OFF”
connections on the back of the control panel.
Notice:
When installing fittings be sure to hold the silver bulkhead fitting in the back of
the unit with one wrench and tighten the fitting being installed with a second wrench.
2.
Connect the “DISPENSE ON” and “DISPENSE OFF” from the valve to the back of the
controller using the 1/4” air line tubing supplied with the valve.
3.
Add the dispense tip to the valve.