![Henkel Loctite 98427 Operation Manual Download Page 30](http://html1.mh-extra.com/html/henkel/loctite-98427/loctite-98427_operation-manual_2123968030.webp)
6.4.2 A Single 90 Degree Arc
Program Data:
Variables
Units
Value
# Events
1
Auto Repeat Time
Seconds
20.0
Start Position 1
Degrees
90.0
Timer A1
Seconds
0.60
End Position 1
Degrees
180.0
Timer B1
Seconds
0.25
Rotating Speed 1
RPM
20 rpm
Function timing diagram and illustration of dispense pattern:
180°
0°
90°
90°
Down
Up
Off
On
180°
0°
Sl
ew RP
M
20
RPM
Sl
ew
RPM
Dispense
Slide Position
1
2
3
4
5
6
1. Slew RPM (Global)
2. Dispense Delay (Global)
3. Timer A
4. Start Position
5. Timer B
6. End Position
30