12 / 208
N000924 12/2010
Magic 600
ATTENTION: Ther is no longer any protection by
switching off the load after the reset.
Teach the door
operator in again before re-commissioning. For this carry out
Teaching in the door operator (Chapter 15)
.
Reset (saved values of the teach-in runs)
During one of the 3 status messages A, B or C (see Chapter
10) press the pushbuttons
and Menu
simultaneously
for longer than 8 seconds and less than 10 seconds. The
indicator lamp flashes (
r)
, then the status message is
displayed; the reset is carried out.
The remote transmitters are not deleted.
Reset, factory setting
• Pull out the plug (1).
• During one of the 3 status messages A, B or C (see 10)
press the pushbuttons
and Menu
simultaneously for
longer than 12 seconds. The indicator lamp flashes slowly
at first, then quicker (
rES).
Then the status display
reappears, the reset is made.
The values shown under
Programming
are
set. The remote transmitters are not reset.
Photo cell
Function:
When the safety input is activated (opening the
contact) the operator stops and reverses as far as the OPEN
end position.
If the “automatic closure” function is also activated, following
the third successive obstruction message, the operator will
move to the OPEN end position and shut down.
Connection
: Pull out plug with yellow bridge on the external
junction 2 and store it. Plug on safety device.
Safety rail, opto-sensor
and
warning light
are
connected by extension modules.
EMERGENCY stop
Function
: If the external safety device is operated when the
door is moving (Contact opened), the door stops immediately.
Once the EMERGENCY stop contact has closed, the door
operator can be moved again with the next pulse.
Connection
: Pull out plug with green bridge on the external
junction 5 and store it. Plug on safety device.
Additional lighting
Connection must be performed only by qualified electricians.
In addition to the operator light (40W), optional lighting of a
maximum of 60 W (no tubular fluorescent lamps) can be
connected to terminals 1 and 2.
Note:
Some energy saving lamps can interfere with the radio
signal.
External pulse input
An external pulse signal (e.g. wall button) can be connected
to terminals 18 and 19.
Additional antenna
An external antenna can be connected to terminals 21 and 20
(GND). The internal antenna (terminal 21) must be
disconnected.
Figure: Control board See also page 164.
Interference frequencies
The wireless signals of other 433 MHz transmitters can
interfere with the door operator.
Self-test
The system runs a self-test after initialisation, after each
motor operation and after every 2.25 hours in idle mode.
Error free = status message.
Troubleshooting
: Reset (Chapter 19) and then perform work
Teaching in the door operator (Chapter 15)
If the error occurs again, request customer service.
Note
: If the same error occurs in two successive self-tests,
the control system will be disabled (commands are rejected).
After approximately one further minute, the system runs
another self-test. If no errors are detected, the control system
is enabled again. If the error persists, a reset will need to be
performed. This will delete all settings and the door operator
will have to be taught in again.
Causes of errors/Remedies
19 Reset
20 Attaching additional safety devices
21 Additional connections
22 Troubleshooting
Error messages*
2
EEprom data
3
Current measurement
4
Hardware Photo cell
5
Switch off thyristors
6
Switch off relay
7
Watchdog test
8
ROM test
9
RAM test
Description
Possible cause/Remedy
Door operator light
flashes evenly
The door has hit an obstruction, do
function test
Door operator light
flashes at intervals of
4
Door operator is not taught in,
attention no protection by load
switch-off! Carry out door operator
Entrapment
protection device not
working.
Incorrect setting of door or
entrapment protection device /
Reset and teach in again
The operator is not
working at all.
None or wrong voltage supply / The
fuse of the motor control is defective
/ Check external terminals 7 and 8.
The operator is
defective.
The slides are not snapped-in
properly./The toothed belts are not
tensioned correctly./The door
thresholds are frozen.
1
2
21
20
19 18
Summary of Contents for Magic 600
Page 2: ......
Page 4: ......
Page 80: ...76 208 N000924 12 2010 Magic 600 4 8 2 2002 96 EG WEEE 27 28...
Page 115: ...Magic 600 N000924 12 2010 111 208 164 S1 S2 195 196 4 15 reset 7 8 4 15 reset LED 16 23 24...
Page 159: ...Magic 600 N000924 12 2010 155 208 A B C 2 1...
Page 161: ...Magic 600 N000924 12 2010 157 208 G A B 5 15 mm C 100 mm B C B C A 150 mm A 150 mm...
Page 162: ...158 208 N000924 12 2010 Magic 600 Einbauma e D G3 G2 D D G4 D G1 N001452...
Page 163: ...Magic 600 N000924 12 2010 159 208 H A A 100 150 mm A 150 350 mm...
Page 168: ...164 208 N000924 12 2010 Magic 600 Sicherung wechseln 1 2 3 5 S1 S2 4...
Page 211: ......