Figure 9.1 Wiring Diagram - PRIMO with Passive Heat Only
RC300 4.5V DC
(AAA X 3)
2273-308
2310-211
6V TRANSFORMER
BLK
BLK
2206-299 LOCK OUT
RESET SWITCH
2196-150
PVI MODULE
2196-200 PVI-WIRE HARNESS
LED’S
2310-062
2155-204
LED SWITCH
2155-752
2166-335 AUX
2155-755
107-558A MALE/FEMALE
WIRE HARNESS
PVI-SLP-B
VERTICAL TERMINATION ONLY
2155-033
JUMPER
WIRE
PVLP-SLP
RECOMMENDED
2310-204
THERMODISC
PVI-SLP-B OR PVLP-SLP POWER VENT REQUIRED
PVLP-SLP RECOMMENDED
2300-753
JUMPER WIRE
PVI-WHXX
RED
BROWN
2179-300
2159-310
SEE THROUGH ONLY
JUNCTION BOX
110-120 VAC
2012-206
JUMPER
WIRE
NOTICE:
This accessory
must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code CSA C22.1.
9. Wiring Requirements
Electrical Service and Repair
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
The PRIMO model requires electrical power in order
to operate the required power vent. If electrical power
service is interrupted during operation of this model, the
appliance will not operate.
Battery power is not an
option on the PRIMO.
Figure 9.1 shows the wiring configuration for the Passive
Heat heat management systems.
The Passive Heat kit may be installed with HEAT-
OUT-PRIMO. A wall switch is required to operate the
HEAT-OUT-PRIMO. Refer to the instructions included