4600 SERIES CONCEALED VERTICAL ROD EXIT DEVICE
INSTALLATION INSTRUCTIONS FOR ALUMINUM DOORS
I
-
ED01933
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325
-
9995 www.hagerco.com
DEVICES COVERED IN THIS DOCUMENT:
4600C—NARROW STILE CONCEALED VERTICAL ROD EXIT DEVICE (CVR)
4600K—NARROW STILE CONCEALED VERTICAL ROD LESS BOTTOM ROD EXIT DEVICE (CLB)
CONCEALED VERTICAL ROD
EXIT DEVICE
CONCEALED VERTICAL ROD
EXIT DEVICE
DOOR
DOOR
APPLICATION
TOOLS REQUIRED
CHASSIS MOUNTING SCREWS
METAL SURFACE MOUNTING
THROUGH BOLTING
For metal doors, tap drill with a
#7 bit. Tap
1/4”
-
20.
Drill
5/16”
through from device
side. Drill
3/8”
from pull side.
Check building codes to see if
your application requires the use
of sleeve nuts and bolts.
Rev 3, Rev Date: 2/13/20